Isolation separates high-voltage circuits from the low-voltage circuits people touch. Isolation distances, isolated gate drivers and safe working.

GROUND EMBEDDED · NOTEPower Electronics 07Isolation and safetyNSABC

Why isolate

  • Protecting people: so mains or a high-voltage battery never reaches USB, the debugger or a hand
  • Separating noise and grounds: so the large currents of an inverter do not disturb signal ground
  • Potential difference: driving places whose reference potential keeps changing, such as a high-side gate

Isolation devices

MCUlow-voltage sideIsolatoroptocoupler · digital isolatorGate driverhigh-voltage side
Between the high-voltage side and the control side sits a device with no direct electrical path.
Device Use
Optocoupler Digital signals, slow
Digital isolator (capacitive / magnetic coupling) Fast SPI, UART, CAN
Isolated gate driver MOSFETs/IGBTs in high-voltage inverters
Isolated DC-DC Power for the isolated side
Isolation amplifier, isolated ADC Measuring current and voltage on the high-voltage side
RoadmapSee where this note sits in Power Electronics→

PCB isolation distances

  • Creepage: distance measured along the surface. Important because dust and moisture cause surface leakage
  • Clearance: straight-line distance through air

They are set by standards (IEC 62368, IEC 60664) according to voltage and pollution degree. If they fall short, cut a slot in the PCB to lengthen the creepage.

Safe working

  • Voltage remains on the DC-link capacitor after power is off. Confirm discharge before working
  • Do not clip an oscilloscope ground to a high-voltage node → use a differential probe
  • Isolation transformer, one-handed working, protective equipment