Ground Embedded KO Subscribe

Notes / Practical Components

Choosing fuses and protection devices

Polyfuses, ordinary fuses, TVS diodes, varistors. Decide first what you are protecting against and the part follows.

GROUND EMBEDDED · NOTEPractical Components 06Fuses and protection partsVCC 3.3V10kΩButtonMCUGPIOHIGH when released

Fuses

Type Characteristics Where used
Fast-acting fuse Blows quickly Protecting semiconductors
Time-delay fuse Withstands inrush current Motors, inputs with large capacitors
Polyfuse (PTC) Resets automatically, high resistance USB, low power

Choose the current rating at 1.25 to 1.5 times the normal maximum current, and the breaking capacity above the largest current that can flow in a fault. A battery's short-circuit current is hundreds of amps, so a fuse with a small breaking capacity can burst from the arc as it blows.

TVS diodes

They react within nanoseconds and absorb ESD and short surges.

  • Working voltage (VRWM): above the normal signal voltage
  • Clamping voltage (VC): below the absolute maximum rating of the chip being protected
  • Unidirectional / bidirectional: bidirectional if the signal also goes negative
RoadmapSee where this note sits in Practical Components→

Varistors (MOV)

They absorb high-energy surges (lightning, inductive loads) but react slowly and degrade with repetition. Used mainly on AC mains inputs.

Combination

Power inputFusesustained overcurrentTVSmomentary overvoltageCircuit
Protection devices work together. The TVS clamps the overvoltage, and if that current lasts, the fuse blows.

Place them in the order input fuse → TVS → reverse-polarity protection, and when a large overvoltage persists, the TVS fails short and blows the fuse, saving the board.

FREE PDFGet the 3 free ebooksIf you want to keep reading this topic as one book: BLDC motor control, serial communication and sensors at book length. PDFs are in Korean.Get them free →